PR.45EL
230 Vac
Irreversible 230 Vac electromechanical geared motor | Built-in electromechanical open and close limit switches | Sturdy articulated anti-shearing arm in galvanised steel
Arm not included
Motor supply | 230 Vac (50-60Hz) |
Max absorbed current | 1.45 A |
Torque | 300 Nm |
Opening time | 20” |
Duty cycle | 30% |
Protection level | IP44 |
Built-in control unit | |
Encoder | |
Operating temperature | -20°C /+50°C |
Lubrication | GREASE |
Leaf max dimension | 4.0 m |
Weight | 10.5 kg |
N. motors per pallet | 42 |
BRAINY
APPLICATION
1 or 2 actuators for swing gates, opposed sliding gates, hydraulic operators, and industrial folding doors
CONTROL UNIT POWER SUPPLY
230 Vac - 50/60 Hz
MOTORS POWER SUPPLY
230 Vac / 600 W + 600 W
MAIN FUNCTIONS
Integrated LCD display | Integrated 433.92 MHz 64-code radio receiver with 3 encoding systems (Advanced Rolling Code, Rolling Code, Fixed Code) | Removable terminal boards | Automatic, semi-automatic and deadman’s logic | Encoder input to detect obstacles | Separate limit switch inputs for each motor | Open, close, pedestrian, step by step and stop inputs | Separate photocell inputs in opening-closing and in closing phases | Input for N.C or 8K2 sensitive edge | Output for electric lock 230 Vac and 12 Vac/dc | Outputs for configuration as gate open indicator, service light, second radio channel and photocell testing | Output for connecting flashing light | Autosetting of operating parameters (with motors equipped with encoder) | Separate electronic torque adjustment for each motor and operating times | Adjustable slow-downs | Advantouch system to configure parameters and manage radio transmitters| Number of maneuvers | Programming access password | Maintenance warning
HEADY
APPLICATION
1 or 2 actuators for swing gates
CONTROL UNIT POWER SUPPLY
230 Vac - 50/60 Hz
MOTORS POWER SUPPLY
230 Vac / 500 W + 500 W
MAIN FUNCTIONS
Integrated LCD display | Integrated 433.92 MHz 64-code radio receiver with 3 encoding systems (Advanced Rolling Code, Rolling Code, Fixed Code) | Removable terminal boards | Automatic, and semi-automatic logic | Step by step, pedestrian and stop inputs | Separate photocell inputs in opening-closing and in closing phases | Output for electric lock 230 Vac/service light | Output as gate open indicator, second radio channel and photocell testing | Output for connecting flashing light | Separate electronic torque adjustment for each motor and operating times | Fixed slow-downs | Advantouch system to configure parameters and manage radio transmitters | Number of maneuvers | Programming access password | Maintenance warning