CP.SAM

CP.SAM
CP.SAM | Internal control units | Automatismi Benincà
Download the instruction manual

Control unit that manages the encoder for maximum precision during the automation manoeuvring steps

Encoder signal recreated by the control unit beginning with the measurements of electric motor operation parameters. It is possible to manage slowing optimally and trace gate travel while providing the torque data in relation to its position to guarantee maximum safety

Intelligent power control system that allows obtaining dynamic data through a precise calculation of the thrust. The system is able to locate any critical points and adjust the torque accordingly in relation to actual requirements and according to measured performance

433.92 MHz Receiver equipped exclusively with Advanced Rolling Code (ARC)

This function automatically adjusts the operational parameters for simplifying the system’s installation and testing operations

This is used to set the number of cycles after which the required maintenance of the system is signaled

This allows a code to be entered for protection of the control unit programming, to prevent access to menus and modification of parameters

This is a protocol for connection with KNX home automation systems by connection of the X.BE card (optional)

Predisposition to manage the control unit using the BeUP app and pro.UP accessory which, by recreating the control unit menu, makes it possible to adjust parameters and logic, read error messages and update the firmware. It is possible to perform remote diagnostics, check the status of the gate and send commands.

512 transmitters storable inside the receiver

Identifies motors or control units with power consumption in standby mode of ≤ 0,8 W.

CP.SAM

APPLICATION

2 actuators for SAM series swing gates

CONTROL UNIT POWER SUPPLY

230 Vac - 50/60 Hz

MOTORS POWER SUPPLY

24 Vdc / 5.5 A + 5.5 A

POWER CONSUMPTION IN STAND-BY

0.8 W

MAIN FUNCTIONS

Integrated LCD display | Integrated radio receiver 433.92 MHz 512 codes with ARC coding | Removable terminal boards | Automatic, semi-automatic and Deadman logic | Separate encoder inputs for each motor | Open, close, step-by-step and pedestrian inputs | Input for active photocell in opening-closing and active photocell only in closing | Input for N.C. or 8K2 sensitive edge | Output for electric lock 12/24 Vdc | Two outputs configurable as open gate signal light, courtesy or zone light, second radio channel, photocell testing, flashing light, alarm contact | Autoset of operating parameters | Separate electronic torque adjustment for each motor| Anti-crushing safety through amperometric detection and encoder management | Electronic torque adjustment with automatic calculation for each point of the stroke (STC SYSTEM) | Separate adjustable slowdowns for each motor | Possibility of encoder- or time-based operation (managed through virtual encoder) even independently between the two motors | Built-in energy saving system ESA+ | Set up for connection to KNX systems via X.BE card (optional) | Designed for managing, configuring, diagnosing and updating firmware through the BeUP app, using the PRO.UP accessory | Advantouch system to configure parameters and manage radio transmitters | Number of manoeuvres | Programming access password | Maintenance warning | Built-in battery charger, compatible with 2 batteries 12V 1.2Ah

Technical Drawing CP.SAM
Terminal Diagram CP.SAM