Barrier EVA.5

24 Vdc barrier for intensive use with integrated control unit, encoder and battery charger
EVA.5 | Road barriers & car park saver | Automatismi Benincà
Download the instruction manual

24 Vdc

For passages up to 5.0 m

Integrated device that guarantees maximum precision during the automation manoeuvring steps

Intelligent power control system that allows obtaining dynamic data through a precise calculation of the thrust. The system is able to locate any critical points and adjust the torque accordingly in relation to actual requirements and according to measured performance

64 transmitters storable inside the receiver

EVA.5

24 Vdc | intensive use

24 Vdc barrier for intensive use with integrated control unit, encoder and battery charger | Switching power supply 100÷250 Vac which reduces energy consumption and ensures a long lifespan of the actuator | Integrated absolute encoder, which ensures greater precision in slowdowns and advanced control of the boom movement so that it never loses the reference position of the boom even if there is a power cut or the automatic device is released | Integrated STC System for precise torque calculation | Easy installation and possibility of quick connection for operation of opposed barriers, thanks to the SIS accessory board | LED.AL5 arm lights with adjustable intensity | Reduced energy use on stand-by | Possibility to install FTC.S photocells using concealed system so that they are perfectly integrated | Integrated flashing lamp (requires EVA.LAMP accessory)

Foundation plate not included

Power supply 100 ÷ 250 Vac (50-60Hz)
Motor supply 24 Vdc
Max absorbed current 3.1 / 1.6 A
Torque 205 Nm
Opening time 3.5” ÷ 6”
Duty cycle intensive use
Protection level IP44
Built-in control unit
Integrated receiver
Encoder
Operating temperature -20°C /+50°C
Lubrication GREASE
Passage width 5.0 m
Weight 54.8 kg
N. motors per pallet 9

CP.EVA

APPLICATION

1 road barrier series EVA.5, EVA.7, EVA.8

CONTROL UNIT POWER SUPPLY

100 ÷ 250 Vac - 50/60 Hz

MOTORS POWER SUPPLY

24 Vdc / 10 A

MAIN FUNCTIONS

Integrated LCD display | Integrated 433.92 MHz 64-code radio receiver with 3 encoding systems (Advanced Rolling Code, Rolling Code, Fixed Code) | Absolute encoder management | Removable terminal boards | Automatic, semi-automatic and deadman’s logic | Motor limit switch inputs | Open, close, step by step, photocell and stop inputs | Output for LED.ALx accessory, integrated LED on arm | Output configurable as open barrier indicator light, second radio channel of incorporated receiver, arm light, service light, photocell test or maintenance indicator | Output for connecting flashing light | Predesigned for the operation of opposed barriers with SIS synchronisation board (optional) | Autosetting of operation parameters | Electronic torque adjustment with automatic calculation for each point in the stroke (STC SYSTEM) | Anti-crushing safety thanks to amperometric obstacle detection | Adjustable slow-downs | Number of maneuvers | Programming access password | Maintenance warning | Integrated battery charger, compatible with battery models DA.BT2/DA.BT6

Technical Drawing EVA.5
Terminal Diagram EVA.5